Resistance to Sliding: Friction, Binding and Notching in Orthodontics
Key points
- Orthodontic resistance to sliding is a group of contact phenomena, not a synonym for friction alone.
- Static friction concerns starting motion; kinetic friction concerns surfaces already sliding, but orthodontic motion is often intermittent and low velocity.
- Binding begins when deflection or angulation brings the wire into contact with bracket corners; contact geometry controls when this transition occurs.
- Notching is permanent local wire deformation that can catch on a bracket corner and temporarily arrest sliding.
- Laboratory results depend strongly on wire, bracket, ligation, normal force, angulation, interbracket distance, saliva or dry conditions, velocity and test history.
What does resistance to sliding mean?
In a sliding arrangement, a bracket and its retaining element are intended to move relative to an archwire, or the wire is intended to move through the bracket. The force needed to produce that relative motion is commonly called resistance to sliding. It is a measurement description rather than a single material constant. The measured value can contain several mechanisms at the same time: friction at contacting surfaces, mechanical interference caused by wire deflection, and permanent deformation at a contact corner. Burrow’s critical review emphasized that the latter two mechanisms can be more important than classical friction once a bracket is no longer aligned with the wire. [1]
This distinction matters because a simple “low-friction” label can hide the contact geometry. A straight wire in an aligned slot may show mainly surface friction. The same wire, bracket and ligature can show a different resistance after the bracket tips, the wire bends between brackets, or a normal force presses the parts together. A resistance-to-sliding result therefore describes the tested assembly under stated conditions; it does not automatically describe every clinical movement or predict an individual response.
Static and kinetic friction
Friction is a tangential force that opposes relative motion between contacting surfaces. In the elementary model, its magnitude is related to the normal force pressing the surfaces together and a coefficient that summarizes material and surface conditions. [4] Static friction is the resistance while contact is still locked: the applied tangential force must reach a limiting value before sliding starts. Kinetic, or dynamic, friction is the resistance while the surfaces are already moving relative to one another. The two values need not be identical.
Orthodontic sliding is not a perfectly continuous engineering motion. Tooth-and-bracket systems can alternate between sticking, brief release, small displacement and renewed contact. This makes the boundary between static and kinetic friction less tidy than in a continuously driven machine. The low-velocity friction literature also shows why test speed, surface roughness, normal force and lubrication state matter. [4] A force trace may therefore include a start peak followed by a different moving level, and those values should not be treated as interchangeable.
At the bracket–wire interface, friction can arise at several contacts rather than at one ideal plane. The wire may touch slot walls, a ligature or a slide, and surface irregularities create microscopic contact points. Material pairing, surface finish, contamination, saliva, ligation pressure and the direction of motion can alter those contacts. These variables are why comparisons between systems are meaningful only when the test design is described carefully.
Binding: when geometry creates corner contact
Binding is a mechanical interference phenomenon. Imagine a bracket initially aligned with a wire. If the bracket tips relative to the wire, or if the wire deflects between brackets, the wire can touch two opposing corners of the slot or bracket wings. The wire is no longer simply sliding along a nearly parallel surface; it is being pressed against edges while the assembly tries to move. Normal forces at those corners can become large, so the resistance is no longer adequately represented by a friction-only equation. [1]
Kusy and Whitley used bracket and archwire dimensions to derive critical contact angles: a geometric boundary between a passive configuration dominated by classical friction and an active configuration in which binding is present. The exact angle is not a universal clinical cutoff. It depends on slot and wire dimensions, bracket engagement and the assumptions of the model. Their work is useful because it links a visible idea—corner contact—to measurable dimensions without pretending that one number applies to all assemblies. [2]
Binding can be produced by more than one source of deflection. A bracket may be tipped in the plane of the slot, the wire may curve across the distance between brackets, or the load may change the orientation of the contact. Interbracket distance also matters because a longer unsupported wire segment can flex differently from a shorter segment. The interface is therefore a coupled system: wire stiffness, bracket spacing, bracket engagement and angulation interact rather than acting as isolated switches.
Notching: a permanent catch
Notching is different from elastic binding. Under sufficiently severe local contact, the wire can undergo permanent deformation at the bracket corner. That deformed region forms a notch or catch. While the notch remains engaged with the corner, the assembly may stop sliding even though the applied load continues. Motion can resume when the notch is released, the geometry changes, or the contact is otherwise displaced. This is why a stop in a force trace should not automatically be interpreted as high surface friction.
The word “permanent” is important in the mechanics description: a temporarily bent wire can spring back, whereas a notch is a lasting local change in shape. Whether notching occurs depends on contact angle, wire cross-section, stiffness, material yield behavior, bracket geometry and the loading history. It is not a property that can be inferred from a brand name alone. Burrow’s review describes notching as a mechanism that can temporarily stop movement, while the experimental literature distinguishes it from the elastic contact of binding. [1]
Why contact geometry matters
Contact geometry connects the three mechanisms. With a small relative angle and adequate clearance, the wire can translate while touching surfaces: classical friction is the useful first description. As the angle or deflection increases, the wire approaches opposing corners. The available clearance, the wire’s occluso-gingival and buccolingual dimensions, and bracket slot dimensions determine how soon that corner contact appears. A larger or stiffer wire can change both the free space and the force needed to bend it; cross-sectional shape matters because the two dimensions do not contribute in the same way.
When contact conditions produce permanent wire deformation, the corner can indent the wire. This is the transition from reversible elastic binding to irreversible notching. [1] [2] The transitions are not magic lines in every experiment. Surface roughness, edge radius, manufacturing tolerances, ligation, bracket engagement and the history of previous passes can shift a measured trace. It is safer to describe them as regimes in a particular test than as fixed clinical thresholds.
Contact states form a continuum
It is useful to picture resistance to sliding as a continuum of contact states rather than as three completely separate choices. Initially, the wire and bracket are relatively aligned, so motion is surface sliding with enough clearance to continue; friction is then the closest first description. [1] [4] As the angle changes or the wire bends between brackets, clearance narrows and the wire approaches a slot or wing edge. Corner contact becomes part of the motion, and resistance combines friction with the normal contact forces characteristic of binding. [1] [2] When contact conditions produce permanent wire deformation, notching appears: this is no longer only elastic pressure that disappears with realignment, but a protrusion or notch that can catch until the contact changes or releases. [1] This sequence explains why a force trace may move from a sliding level to a peak or pause without one mechanism remaining constant throughout the test.
The test fixture is part of this continuum. Slot shape, edge radius, wire engagement and the retaining method determine where the wire touches and how force is distributed; bracket angle relative to the wire can differ from wire curvature across the interbracket span. [2] Interbracket distance changes the unsupported segment, while cross-section changes clearance and bending response. A small change in mounting or pull direction can therefore move the interface from surface sliding to corner contact even when other components appear similar. [2] [5]
Pull angle also complicates comparison: a force that is not parallel to the wire path can change pressure on one edge and promote or release opposing contact. A reading after a dwell can differ from a continuous pass or repeated passes because the test responds to contact and loading history rather than recording an isolated number. [2] [5] The term “critical contact angle” should therefore be read as a result of specified geometry, dimensions and model assumptions, not as a fixed limit for every device or mounting method. [2]
Dry and wet conditions should not be treated as interchangeable. Saliva can alter surface contact, but its effect depends on alloy, surface finish, normal force and geometry; the 2000 Kusy–Whitley study compared dry and human-saliva states while varying other factors, and the systematic review emphasized that protocol differences limit direct comparison. [3] [5] The meaning of a value therefore depends on the test fixture, wetness and loading together, not on the material name alone.
Why experiments do not all agree
A resistance-to-sliding experiment needs to specify at least the bracket and wire materials, dimensions and surface condition; the ligation or retaining mechanism; the amount of bracket engagement; the normal force; the relative angle; the interbracket distance; the sliding direction and speed; and whether the setup is dry or wet. Saliva can act as a lubricant in some contacts, but its effect is not a universal constant across alloys and configurations. The 2000 Kusy and Whitley study, for example, explicitly compared dry and human-saliva conditions, varied interbracket distance and engagement, and identified a boundary between passive friction and active binding in its test system. [3]
Test history is another source of variation. Repeated loading can change surfaces or leave a prior deformation, so a later pass is not necessarily equivalent to the first. Bracket alignment, mounting rigidity and the way force is measured can also change the apparent result. A systematic review by Savoldi and colleagues argued that methodological variation is a major problem and proposed a protocol framework rather than treating every published resistance value as directly comparable. [5]
Material comparisons require the same caution. Wire size, cross-section and stiffness are interdependent variables. A result for a round wire cannot be generalized to a rectangular wire without checking the contact geometry and the tested engagement. The article therefore avoids ranking appliances or giving force thresholds.
Reading a force trace without overinterpreting it
A sharp initial peak may be consistent with static friction, but a peak can also reflect contact interference or an instrument’s acceleration. A lower plateau may represent kinetic friction, yet an intermittent trace can reflect repeated stick–slip or release of a corner contact. A flat pause can be compatible with notching, but the trace alone cannot prove the wire’s shape changed unless the test inspects the interface. Labels such as “frictional resistance” should therefore be checked against the apparatus and definitions used by the authors.
The most defensible interpretation is layered. First ask whether the components were aligned or angulated. Next ask whether normal force and clearance were controlled. Then ask whether the wire could bend between brackets and whether the test could detect permanent deformation. Finally check speed, wetness, repeat passes and measurement direction. Without those details, a numerical comparison may have less meaning than its precision suggests.
Limits of this educational model
These diagrams show an idealized bracket–wire contact, not a patient, a prescribed appliance, or a prediction of movement. They omit biological support, three-dimensional tooth response, oral variability and many details of appliance manufacture. They also do not convert a laboratory resistance into a clinical outcome. “Orthodontic resistance to sliding friction” is a useful search phrase, but the underlying concept is broader: friction, binding and notching can coexist and can change as geometry changes.
In short, friction describes tangential resistance at surfaces; binding describes corner contact caused by relative angulation or deflection; and notching describes permanent local wire deformation that can catch. Experimental claims should name the regime and the test conditions. This separation keeps a basic mechanics explanation accurate without drifting into treatment choices, force prescriptions or appliance marketing.
References
- Burrow SJ. Friction and resistance to sliding in orthodontics: A critical review. American Journal of Orthodontics and Dentofacial Orthopedics. 2009;135(4):442–447. PubMed · DOI.
- Kusy RP, Whitley JQ. Influence of arch wire and bracket dimensions on sliding mechanics: Derivations and determinations of the critical contact angles for binding. European Journal of Orthodontics. 1999;21(2):199–208. PubMed · DOI.
- Kusy RP, Whitley JQ. Resistance to sliding of orthodontic appliances in the dry and wet states: Influence of archwire alloy, interbracket distance, and bracket engagement. Journal of Biomedical Materials Research. 2000;52(4):797–811. DOI.
- Prashant PS, Nandan H, Gopalakrishnan M. Friction in orthodontics. Journal of Pharmacy and Bioallied Sciences. 2015;7(Suppl 2):S334–S338. PubMed · DOI.
- Savoldi F, Visconti L, Dalessandri D, Bonetti S, Tsoi JKH, Paganelli C. Resistance to sliding in orthodontics: misconception or method error? A systematic review and a proposal of a test protocol. Korean Journal of Orthodontics. 2018;48(4):268–280. PubMed · DOI.
Related reading
- مقاومة الانزلاق في التقويم: الاحتكاك والانحشار والتثلمThe same topic in Arabic
- Center of resistance and rotation in orthodonticsA separate force-system article
- All articlesOrthodontic analyses and research guides
This article is for education. Clinical decisions remain the responsibility of the treating clinician.